Skip to main content
7146
Lab Test Details

Lab Test Details

SIM

12670 

CPT

80202 

Synonyms

Vanc T 

Specimen Type

Plasma or serum 

Container

3.5 ml Green - Lithium heparin plasma separator 
4.0 ml Gold-top serum separator 

Collection Instructions

None

Volume

2 ml plasma or serum, minimum 0.5 ml

Additional Information

Draw before medicine is given.

Patient Preparation

none

Specimen Processing Instructions

Plasma:  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Serum:  Allow to clot.  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Centrifuge within 2 hours of collection.

Transport Requirements

Refrigerated

Specimen Stability

Room temperature:  8 hours   Refrigerated:  5 days 

Rejection Criteria

If not centrifuged within 2 hours of collection.

Reference Range

10 - 20 µg/mL

Critical Value

> 20 µg/mL 

Test Includes

Vancomycin 

Methodology

Homogeneous Enzyme Immunoassay Rate method 

Testing Frequency

Daily, Monday - Sunday 

 

 

Reviewed By

Sandy Hammett 

Reviewed Date

1/31/2018

Supplemental