Skip to main content
8431
Lab Test Details

Lab Test Details

SIM

20550 

CPT

85032 

Synonyms

Manual PLT 

Specimen Type

Whole Blood 

Container

3.0 ml EDTA lavender stopper tube

Collection Instructions

None

Volume

2 ml whole blood 
Min: 1.0 ml 

Additional Information

none

Patient Preparation

none

Specimen Processing Instructions

Refrigerated

Transport Requirements

Refrigerated

Specimen Stability

Room temperature:  8 hours   Refrigerated: 24 hours 

Rejection Criteria

•  Clotted Sample 
•  Insufficient volume 
•  Plasma has been removed.

Reference Range

Female = 141 - 359 cu mm

Male = 119 - 332 cu mm

Critical Value

Platelet Count = <30,000 cu mm and >1,000,000 cu mm 

Test Includes

Platelet Count 

Methodology

Beckman Coulter DxH Automated Hematology analyzer 

Testing Frequency

Daily, Monday - Sunday 

 

 

Reviewed By

Sandy Hammett 

Reviewed Date

2/2/2018

Supplemental