Skip to main content
8316
Lab Test Details

Lab Test Details

SIM

50085 

CPT

82746 

Synonyms

Folic Acid 

Specimen Type

Serum 

Container

4.0 ml Gold-top serum separator

Collection Instructions

None

Volume

2 ml serum, minimum 0.5 ml

Additional Information

none

Patient Preparation

none

Specimen Processing Instructions

Serum:  Allow to clot.  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Centrifuge within 2 hours of collection.

Transport Requirements

Refrigerated

Specimen Stability

Room temperature:  8 hours   Refrigerated: 2 days

Rejection Criteria

If not centrifuged within 2 hours of collection.

Reference Range

>5.4 ng/ml

Critical Value

none 

Test Includes

Folate 

Methodology

Chemiluminescent technology 

Testing Frequency

Daily, Monday - Sunday 

 

 

Reviewed By

Crystal Killian

Reviewed Date

3/18/2021

Supplemental

 

  

Reviewed by Summer Brochu 11.17.21