Lab Test Details
20150 |
|
85240 |
|
|
|
Sodium Citrate Plasma |
|
Two tubes – 4.5 ml Sodium Citrate 3.2% Blue stopper tube |
|
None |
|
4 ml plasma |
|
Centrifuge at 3380 rpm’s (±100) for 5 minutes |
|
none |
|
Whole Blood: send the collection tube Plasma: Centrifuge at 3380 rpm’s (±100) for 5 minutes. Remove the plasma without disturbing the cellular layer. Centrifuge again at 3380 rpm's (±100) for 5 minutes. Remove the platelet poor plasma to a transfer tube. Freeze sample to extend stability.
|
|
Refrigerated if within 4 hours If transport time exceeds 4 hours send frozen. |
|
Refrigerated Whole Blood: 4 hours; Frozen Plasma: 1 month |
|
• Clotted Sample |
|
Factor VIII = 30 – 100 % activity |
|
None |
|
Factor VIII |
|
Electromagnetic mechanical clot detection system |
|
7am - 7pm only, Daily, Monday - Sunday |
|
|
|
Crystal Killian |
|
3/18/2021 |
|
|
Reviewed by Crystal M. Killian March 18, 2021