Lab Test Details
SIM |
N/A Phone call order to blood bank 67655 with the following information:
Followed by a completed Adult Blood Order form with written order at blood pick up. |
CPT |
N/A |
Synonyms |
Emergent RBC, plasma; Emergency Release of Uncrossmatched Blood; Stay ahead orders; Blood cooler; Transitional Cooler; Critical Care (CC) Cooler; OB Cooler; Whole Blood (WB) Cooler; Stay ahead order; Emerge Cooler; MTP |
Specimen Type |
Stat ordering and collection of Type & Screen is REQUIRED. Transfusion of several units of blood prior to collection of the Type & Screen may make blood typing impossible and antibody screening invalid due to dilution from transfused donor blood. |
Container |
6.0 mL Pink top tube |
Collection Instructions |
Draw Type & Screen immediately |
Volume |
6.0 mL |
Additional Information |
Ordering Information: Any provider: 1) Emergency Release of __#Uncrossmatched RBCL, Plasma units, PLT, or Cryo 2) Stay ahead orders of __# RBC/__# FFP
Surgical hemorrhage: Transitional cooler with Stay ahead order of __# RBC/ __# FFP Ordered by anesthesia or surgeon
OB Hemorrhage: OB Cooler with or without stay ahead order Ordered by anesthesia
Critical Care Protocol: Ordered by Intensivists only
Whole Blood cooler: Limited to eligible trauma patients (females >50 yrs or males)
Emerge cooler (male or female): Limited to trauma patients
MTP: Limited to trauma patients & only ordered trauma attending physician |
Patient Preparation |
N/A |
Specimen Processing Instructions |
Type & Screen testing will initiate ASAP post receipt. Second blood type may be required for patients without a historical blood type on file to enable transitioning to type specific blood products. |
Transport Requirements |
Emergency Release of Uncrossmatched blood may be sent via 6 inch pneumatic tube to applicable areas. All other areas must pick up at blood bank window with proper blood release form. All coolers from blood bank must be picked up at blood bank window with proper blood release form. Whole blood cooler and Emerge cooler are obtained from BloodTrack Emerge in trauma bay. |
Specimen Stability |
N/A |
Rejection Criteria |
Requests made outside of scope outlined above. Adjust order so blood can be provided without delay. |
Reference Range |
N/A |
Critical Value |
N/A |
Test Includes |
N/A |
Methodology |
N/A |
Testing Frequency |
24/7 |
Reviewed By |
Michele Earley |
Reviewed Date |
3/22/23 |