Lab Test Details
SIM |
20291 |
CPT |
85379 |
Synonyms |
Dimertest |
Specimen Type |
Plasma |
Container |
Blue stopper, 3.2% Sodium Citrate |
Collection Instructions |
none |
Volume |
4.5 mL |
Additional Information |
None |
Patient Preparation |
None |
Specimen Processing Instructions |
If sample is collected at an outpatient office where the sample is not sent to the Laboratory within the hour for testing:
|
Transport Requirements |
Refrigerated |
Specimen Stability |
Refrigerated Plasma: 4 hours or Frozen Plasma: 1 month at -20 degree Celsius |
Rejection Criteria |
• Gross hemolysis |
Reference Range |
<0.46 ug/mL FEU (Fibrinogen Equivalent Units) revised 9-7-11 1450 |
Critical Value |
>20 ug/ml FEU |
Test Includes |
D-Dimer |
Methodology |
Antibody-coated latex particles agglutinate to form aggregates of a diameter greater than the wavelength of the light, more of the latter is absorbed. This increase in light absorption is a function of the antigen level present in the test sample. Instrument: Diagnostica Stago Sta R Max. |
Testing Frequency |
Daily, Monday - Sunday |
|
|
Reviewed By |
Crystal Killian |
Reviewed Date |
3/5/2021 |
Supplemental |
|
Reviewed by Crystal M. Killian March 17, 2021